Delivering SmartSequencing outside of the equipment rack, with remote relay.

  • SmartSequencing™ – SmartSequencing allows bidirectional, safe sequenced power up/down operations via the push of a button or turn of a key.
  • Voltage Protection – Extreme Voltage Shutdown (EVS) safeguards from catastrophic under-voltage (under 80V sustained) or over-voltage (over 145V sustained) conditions. The EVS feature can be selectively enabled or disabled according to the preference of the user.
  • Diagnostic Lights – Diagnostic lights provide valuable system information including power quality.
  • 15 Amp Output Current – 15 amp maximum current capacity with incorporated 15 amp thermal circuit breaker.
  • DIP Switch Customization – DIP switches and potentiometer allows customization of settings such as sequencing delays, 12V on/off, and more. Security covers are provided to prevent unauthorized personnel from tampering with DIP switches.

Furman’s Contractor Series MiniPorts extend the benefits of SmartSequencing to electronics outside of the equipment rack, providing tremendous flexibility to any installation scenario. Units may be daisy-chained and fully controlled via a Furman SmartSequencer, legacy Furman sequencer, third-party sequencers, and/or control and automation systems.

DIP switches and potentiometer allows customization of settings such as sequencing delays, 12V on/off, and more. Security covers are provided to prevent unauthorized personnel from tampering with DIP switches.

Sequencing of duplex initiated remotely by standard analog triggering (remote terminal) or digital link (SmartSequencing from CN-1800S or CN-2400S).

The CN-15MP can shut itself off automatically when triggered by a fire alarm.

Specs

  • AC Voltage Input Range - 90-139VAC, 50/60Hz
  • Maximum AC Current Rating - 15 amps (Thermal breaker)
  • AC Cord - 3/14AWG, 10 feet, black, fixed, NEMA 5-15P plug
  • AC Receptacles - 2 NEMA 5-15R’s (1 duplex)
  • AC Undervoltage Protection - EVS, 77VAC+/-3VAC
  • AC Overvoltage Protection - EVS, 140VAC+/-5VAC
  • AC Overvoltage Reset Modes - Manual and Auto-reset (configurable)
  • Operating Temperature Range - 5C (40F) to 40C (105F) degrees
  • Humidity Range - <90% rH (Relative Humidity)
  • Circuit Breaker - Pushbutton, 15A
  • Front panel diagnostic indicators (LED) - Power, Extreme Voltage, Primary Link, Secondary Link
  • Side Panel DIP Switch Features (with security cover) - 1 Minute Delay, 2 Minute Delay, 4 Minute Delay, Force Off NO/NC, 12V Mode On/Off GND Mode On, Momentary/Maintained, Primary/Secondary, EVS Reset Auto/Manual
  • Side Panel Potentiometer - allows fine tune delay adjustments
  • Remote Terminal - +5-30VDC In, 12VDC (12mA) Out
    SmartSequencing - Phoenix-type 4-Pin Connector, Screw Terminals, Primary & Secondary Links (Current Loop – 1000’ nominal)
  • Remote Terminal - Phoenix-type 5-Pin Connector With Screw Terminals; +12V, STAT, REM, GND, DLY_OUT (Class 1 Wiring) Force Off Phoenix-type 2-Pin Connector With Screw Terminals, FORCE OFF (Class 1 Wiring)
  • RS-232 Compatible - Yes, indirectly, when connected via SmartSequencing to a Furman Smart Sequencer with an RS-232 port
  • Voltmeter - Available with SmartSequencing, ± 2VAC accuracy
  • Ammeter - Available with SmartSequencing, ±1A accuracy
  • Power Consumption (No Load) - 10 Watts
  • Safety Agency - CSA, RoHS Compliant